Laminar Flow Design Ceiling Light with Balance Arm for Clinic

  • Audited Supplier
  • 2 yrs

Contact Supplier

Product Highlights

  • Long Lifespan LEDs: Equipped with imported German LED beads, offering a lifespan of over 80,000 hours without the need for bulb replacement.
  • Laminar Flow Design: The fully enclosed, streamlined lamp head meets aerodynamic principles, eliminating air turbulence and meeting high sterile standards for modern operating rooms.
  • Smart Digital Control: Features a touch LCD control panel for precise adjustment of illuminance, color temperature, and lighting modes.
  • Adjustable Color Temperature: Color temperature is adjustable from 3500K to 5000K to reduce eye fatigue for medical staff during long operations.
  • Stable Suspension System: Features a high-quality balance arm with 6 groups of universal joints for 360-degree positioning and stable locking.
  • High Illuminance: Maximum illuminance reaches 180,000 Lux, providing bright and uniform lighting for clear visibility

Product Images of Laminar Flow Design Ceiling Light with Balance Arm for Clinic

Laminar Flow Design Ceiling Light with Balance Arm for Clinic
Laminar Flow Design Ceiling Light with Balance Arm for Clinic pictures & photos
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
Laminar Flow Design Ceiling Light with Balance Arm for Clinic pictures & photos
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
Laminar Flow Design Ceiling Light with Balance Arm for Clinic pictures & photos
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
Laminar Flow Design Ceiling Light with Balance Arm for Clinic pictures & photos
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
Laminar Flow Design Ceiling Light with Balance Arm for Clinic pictures & photos
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
Laminar Flow Design Ceiling Light with Balance Arm for Clinic pictures & photos
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
  • Laminar Flow Design Ceiling Light with Balance Arm for Clinic
  • Laminar Flow Design Ceiling Light with Balance Arm for Clinic
    Laminar Flow Design Ceiling Light with Balance Arm for Clinic
  • Laminar Flow Design Ceiling Light with Balance Arm for Clinic
    Laminar Flow Design Ceiling Light with Balance Arm for Clinic
  • Laminar Flow Design Ceiling Light with Balance Arm for Clinic
    Laminar Flow Design Ceiling Light with Balance Arm for Clinic
  • Laminar Flow Design Ceiling Light with Balance Arm for Clinic
    Laminar Flow Design Ceiling Light with Balance Arm for Clinic
  • Laminar Flow Design Ceiling Light with Balance Arm for Clinic
    Laminar Flow Design Ceiling Light with Balance Arm for Clinic
  • Laminar Flow Design Ceiling Light with Balance Arm for Clinic
    Laminar Flow Design Ceiling Light with Balance Arm for Clinic

Find Similar Products

Product Description

Product Description
Product Introduction: SYYT-LED700+500 Surgical Shadowless Lamp
The SYYT-LED700+500 is a state-of-the-art dual-head surgical lighting system engineered to meet the demanding requirements of modern operating rooms. By integrating advanced LED technology with a sophisticated mechanical design, this system delivers exceptional illumination, superior color fidelity, and unparalleled operational flexibility for a wide range of surgical procedures.
Unmatched Illumination Performance
At the heart of the system is a high-efficiency LED light source that provides brilliant, shadowless illumination. The dual-head configuration, featuring a larger 700mm lamp and a 500mm auxiliary lamp, allows for versatile lighting setups. The system achieves a maximum illuminance of up to 180,000 Lux with a deep lighting depth of over 1200mm, ensuring clear visibility even in deep surgical cavities. The light field is uniform and free of shadows, while the adjustable color temperature (3500K-5000K) and high Color Rendering Index (CRI ≥ 96) enable surgeons to distinguish tissue types with greater accuracy and reduce eye fatigue during long procedures.
Advanced "Cold Light" Technology
A key advantage of the SYYT-LED700+500 is its ability to provide intense light without the associated heat. The advanced LED cold light source emits virtually no infrared or ultraviolet radiation. This ensures that the temperature rise in the surgical field is ≤ 2℃ and at the surgeon's head is ≤ 1℃, creating a more comfortable environment for the surgical team and reducing the risk of tissue dehydration for the patient. With a lifespan exceeding 80,000 hours, the LEDs eliminate the need for frequent bulb replacements, offering a cost-effective and energy-efficient solution.
Superior Design for Sterile Environments
The lamp head features a fully enclosed, streamlined design based on aerodynamic principles. This design minimizes turbulence and eliminates dead zones, preventing the accumulation of dust and bacteria and making it ideal for laminar flow operating rooms where maintaining a sterile environment is critical. The smooth surfaces are also easy to clean and disinfect.
Specification
Maximum Illuminance
180,000 Lux (LED-700) / 160,000 Lux (LED-500)
Color Temperature
3500K - 5000K (Adjustable)
Color Rendering Index (CRI)
≥ 96
Light Field Diameter
150 - 350 mm
Dimming System
Stepless digital dimming
LED Quantity
80 pcs (LED-700) / 48 pcs (LED-500)
Feature
Ceiling Mounted Design
Suspension System
High-Quality Balance Arm
Arm Design
Six-Joint Linkage Mechanism
Visual Comfort
Reduces Eye Fatigue
Product Images
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
Company Profile
Shandong Sanyang Medical Equipment Co., Ltd. is a specialized manufacturer dedicated to the research, development, production, and distribution of medical devices. Headquartered in Plot No. 3, Lingnan Industrial Park, Lingcheng Town, Qufu City, Jining, Shandong Province, the company operates as a limited liability entity with a registered capital of RMB 3 million. Under the leadership of Founder and General Manager Mr. Yuqi Chen, we uphold a commitment to innovation, quality, and reliability in the healthcare industry.
Core Business & Product Portfolio
We specialize in designing and manufacturing high-performance medical equipment, including:
Clinical Solutions: Infant beds, gynecological examination tables, multi-functional surgical beds, LED surgical shadowless lights, and examination lamps.
Veterinary Equipment: Pet grooming stations and veterinary surgical tables.
Disinfection Systems: Non-hazardous medical disinfection devices and sterilizing agents.
Production & R&D Capabilities
Our 3,000-square-meter modern facility integrates advanced production lines with end-to-end manufacturing capabilities—from conceptual design to precision assembly. Committed to technological excellence, we hold multiple patents and registered trademarks in medical device engineering and disinfection technologies. All products comply with stringent national and international quality standards, ensuring safety, durability, and clinical efficacy.
Team & Credentials
Led by industry veterans with decades of collective experience, our team combines technical expertise with market insight. As an accredited A-Level Taxpayer and certified Small-Micro Enterprise in China, we maintain a strong reputation for compliance and operational integrity. Our quality management system adheres to global regulatory requirements, supporting both domestic and international market demands.
Market Reach & Vision
Rooted in the philosophy of "Innovation-Driven Quality, Patient-Centered Care," Sanyang Medical serves healthcare institutions, veterinary clinics, and distributors across China and in overseas markets. We continuously refine our product portfolio to address evolving clinical needs, prioritizing user safety, ergonomic design, and operational efficiency.
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
Laminar Flow Design Ceiling Light with Balance Arm for Clinic
FAQ
Q1: What happens if one of the two heads fails during surgery?
A: Safety is our priority. The dual-head system operates on independent circuits. If one head experiences a malfunction, the other head continues to operate at 100% brightness, ensuring the surgery can proceed safely without interruption.
Q2: What is the lifespan of the LEDs compared to traditional halogen lights?
A: Our high-efficiency LED modules have a service life of up to 60,000 to 80,000 hours. This is significantly longer than halogen bulbs, meaning you will rarely need to replace light sources, drastically reducing maintenance costs and downtime over the years.
Q3: How does the "Laminar Flow" design benefit our Operating Theater?
A: The ultra-thin lamp head (usually <60mm) is aerodynamically shaped to minimize air resistance. This allows the sterile laminar airflow from the ceiling to pass around the light smoothly, reducing turbulence and the risk of airborne contamination in the critical surgical zone.
Q4: How precise is the color rendering for distinguishing tissues?
A: It is extremely precise. With a Color Rendering Index (CRI) of ≥96 and a specific R9 value (red rendering) of ≥97, the light accurately reproduces the subtle color differences between arteries, veins, nerves, and muscle tissue, which is critical for accurate diagnosis and surgical safety.
Q5:Can the light integrate with our existing endoscopy or camera systems?
A: Yes. The central handle is modular and designed to accept various accessories. We offer integration with HD endoscopic camera systems, allowing the surgeon to view internal feeds directly on a screen mounted near the light, or even record the procedure via the light's central axis.
Q6: How does the LED shadowless lamp actually eliminate shadows?
A: The shadowless effect is achieved through an advanced optical design. The lamp head contains multiple independent LED light sources arranged in a circular array. These sources project light from different angles onto the surgical site. If the surgeon's head or hands block the light from one angle, the overlapping light from the other angles fills in the dark spots, creating a highly uniform, shadow-free illumination field.

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASI255163". Items marked "verified" are certified.

Watch Video
Watch Video
Shandong Sanyang Medical Equipment Co., Ltd.
Shandong Sanyang Medical Equipment Co., Ltd.
Shandong Sanyang Medical Equipment Co., Ltd.
Shandong Sanyang Medical Equipment Co., Ltd.
Shandong Sanyang Medical Equipment Co., Ltd.
Shandong Sanyang Medical Equipment Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Jining, Shandong, China
verified Plant Area
3000 square meters
verified Number of Employees
43
verified Registered Capital
3,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Guangzhou Port, Shanghai Port
verified Minimum Order Quantity
1
verified Supply Chain Partners
7

Our Production Capability & Technical Expertise

verified Main Products
Surgical Lights, Operation Lamp, Electric Surgical Operating Table, Veterinary Surgical Table, Pet Hospital Cage, Pet Grooming Table, Emergency Transfer Vehicle of Hospital
verified Production Lines
4
verified Production Machines
Laser Cutting Machine, Laser Pipe Cutting Machine, Bending Machine, Welding Line, Assembling Line
verified QA/QC inspectors
1 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified R&D Engineers
2 people
verified Traceability of Raw Materials
Yes
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2021-01-14
verified Export Year
4 Years
verified Main Markets
North America, Southeast Asia/ Mideast
verified Repeat Buyers Choice
30%~50%
verified Number of Foreign Trading Staff
6
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
Yes

Our Certifications, Standards & Industry Recognition

verified Management System Certification
ISO9001:2015, Others
verified Product Certification
CE
verified Cooperated with Fortune 500
No

FAQ

What is the lifespan of the LED bulbs?
The imported LED bulbs have a lifespan of over 80,000 hours, which means they do not need to be replaced during the normal service life of the lamp.
Can the color temperature be adjusted?
Yes, the color temperature is adjustable between 3500K and 5000K to suit different surgical requirements and reduce eye fatigue.
What is the maximum illuminance?
The maximum illuminance is 180,000 Lux, which can be adjusted steplessly via the control panel.
Is this light suitable for laminar flow operating rooms?
Yes, the lamp head has a fully enclosed streamlined design that meets aerodynamic principles, making it suitable for laminar flow environments.
How is the light focused?
It features a manual stepless focusing system that allows for precise adjustment of the light spot.
What happens if one LED fails?
The lamp head has a low failure rate design. Each module has independent control, so a single LED failure will not affect the overall function.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now